Run a staffed measurement kiosk

Record readings at a shared ward tablet with no patient sign-in, keeping patient details in your own Supabase instead of Ovok.

Complexity
3/5
Clients
Web
Time
45–90 minutes, plus a Supabase instance

Build a measurement station that nurses share during a shift. A nurse signs in once, scans each patient's card, checks the patient's name and date of birth, and saves a blood-pressure reading to Ovok. Patients never sign in.

The patient register (names, dates of birth and card codes) lives in your own self-hosted Supabase. Ovok holds a Patient that carries only a pseudonym, plus the readings. Measurements, Signals and EHR connections work on that Patient as they do on any other.

The finished example is Ovok-Dev/staffed-kiosk-example.

What each system holds

Supabase (yours)Ovok
PatientName, date of birth, card code, pseudonymA Patient with only identifier = the pseudonym
ReadingsNothingBlood-pressure Observations on that Patient
StaffNothingPractitioner accounts; each reading records the nurse who saved it in meta.author
Who can read itThe patients Edge Function, with Supabase's service rolePractitioners of the project, under their access policy

The pseudonym is the register row's id. Only the register can turn it back into a person.

Set upConsole

You need:

  • An Ovok sandbox project and a practitioner account in it.
  • Docker, to run Supabase on your machine. In production you self-host Supabase the same way.
  • Node.js 24 or newer.

Build the kiosk

  1. Set up the patient register
  2. Configure the Ovok project
  3. Add the patients function
  4. Build the kiosk app
  5. Run it on the ward
  6. Optional: Receive readings over HL7 v2

How a reading flows

  1. The nurse signs in to Ovok as a practitioner. The kiosk keeps the session until the browser tab closes.
  2. A scanner types the card code. The kiosk sends it, with the nurse's Ovok token, to the patients Edge Function.
  3. The function asks Ovok who the token belongs to (GET /v1/auth/me) and refuses anyone who is not a practitioner of your project. It returns the patient's name, date of birth and Ovok Patient id.
  4. The nurse checks name and date of birth with the patient, then enters the reading.
  5. The kiosk saves it with ovok.measurements.save({ patientId }). Ovok stores the Observations. For a Patient enrolled in Signals, Ovok forwards eligible readings as Data Ingestion describes.

When a patient is registered, the function creates the Ovok Patient with a conditional create, so a retry never creates a second one.

Optional: send readings to a clinical system

The kiosk's readings are ordinary Observations, so any system can take them through Connect to your EHR:

  • Your own Supabase over HL7 v2: make the connection with the register's identifier system, and every reading comes back with the pseudonym in PID-3. See Receive readings over HL7 v2.
  • A FHIR-native EHR pulls or subscribes to Observations. It finds the patient by the pseudonym, which only your register can resolve.
  • A hospital's HL7 v2 system matches on its own MRN. Store the MRN in the register, add it as a second identifier when the function creates the Patient, and make the connection with the hospital's MRN system. The message carries the MRN with the name and date of birth fields empty; confirm with the hospital's interface team that their system matches on MRN alone.

Test your integration

  1. Register a patient at the kiosk with a test card code.
  2. Scan the card, confirm the identity, and save a reading.
  3. Search Patients in your Ovok project and open the new one.
ScenarioHow to trigger itExpected result
Reading savedSave a reading for a scanned patientIt appears under "Recent readings in Ovok"
No patient details in OvokRead the Patient in OvokIt has identifier and active only
Unknown cardScan a code nobody hasThe kiosk offers to register the card
Card takenRegister a code another patient hasThe kiosk says the card is taken (409)
Patient tokenCall the function with a patient's token403
Station left openLeave a patient on screen for 90 secondsThe kiosk returns to scanning

See also