HL7 message reference

The ORU^R01 message Ovok sends, what is skipped, acknowledgements, retries and resends.

Ovok sends each Observation created in your project, and matched by the connection, as an IHE PCD-01 ORU^R01 message (HL7 v2.6).

Example

ORU^R01
MSH|^~\&|OVOK||||20261111191600+0000||ORU^R01^ORU_R01|<Observation id>|P|2.6|||AL|NE||UNICODE UTF-8|||IHE_PCD_001^IHE PCD^1.3.6.1.4.1.19376.1.6.1.1.1^ISO
PID|1||MRN-9^^^KIS^MR||Muster^Erika||19500307|F
OBR|1||<Observation id>^OVOK|182777000^monitoring of patient^SNOMED-CT|||20261111191530+0000
OBX|1|NM|8867-4^Heart rate^LN|1.0.0.1|72|/min^beats/minute^UCUM|||||F|||20261111191530+0000
SegmentCarries
MSHSender, time, message type, control id, profile
PIDThe patient and the MRN in the hospital's system
OBRThe Observation id and the time of the reading
OBXOne numeric value, with code, unit, result status and time

What is sent

  • One OBX per numeric value: the Observation's own and each component's. A blood-pressure panel sends systolic and diastolic, not the panel.
  • OBX-3 is the MDC code when there is one, then LOINC, then SNOMED CT.
  • Units are UCUM when the quantity carries a UCUM code.
  • Times are UTC to the second, with +0000.
  • OBX-11 maps the Observation status: final F, preliminary P, amended or corrected C, registered I, cancelled X, entered in error W, otherwise R.

What is skipped

Nothing is sent, and nothing is retried, when:

CaseFix
The patient has no identifier in the hospital's systemAdd the MRN, then resend.
The Observation has no numeric value coded in MDC, LOINC or SNOMED CTFix the coding where the reading is produced, or narrow the connection's criteria.

Acknowledgements

Ovok waits up to 10 seconds for the hospital's acknowledgement in MSA-1.

AnswerMeaning
AA, CAAccepted. The delivery is complete.
AE, AR, CE, CRRejected. The same refusal comes back on a retry, so fix the mapping with the hospital's analyst.
No answer in 10 secondsThe agent is offline or the receiver is slow. Ovok retries.

Retries

A delivery that is not accepted is retried with backoff for about 34 minutes. After that the reading is not sent again by itself.

MSH-10 is the Observation id. A retry after a lost acknowledgement carries the same control id, so the hospital can drop a repeated one.

Resend after a long outage

Resend each missed Observation to the one connection, as a create:

resend.sh
curl --request POST "https://api.sandbox.ovok.com/fhir/R4/Observation/${OBSERVATION_ID}/\$resend" \
  --header "Authorization: Bearer ${OVOK_TOKEN}" \
  --header 'Content-Type: application/json' \
  --data '{"interaction":"create","subscription":"<connection id>"}'

See Resend a resource.