Skip to main content

ProdCharacteristic

Base StructureDefinition for ProdCharacteristic Type: The marketing status describes the date when a medicinal product is actually put on the market or the date as of which it is no longer available.

Complex data type in FHIR R4. Maturity: Not stated.

Elements​

ElementTypeCardinalityDescription
idstring0..1Unique id for inter-element referencing
extensionExtension0..*Additional content defined by implementations
modifierExtensionExtension0..*Extensions that cannot be ignored even if unrecognized
heightQuantity0..1Where applicable, the height can be specified using a numerical value and its unit of measurement The unit of measurement shall be specified in accordance with ISO 11240 and the resulting terminology The symbol and the symbol identifier shall be used
widthQuantity0..1Where applicable, the width can be specified using a numerical value and its unit of measurement The unit of measurement shall be specified in accordance with ISO 11240 and the resulting terminology The symbol and the symbol identifier shall be used
depthQuantity0..1Where applicable, the depth can be specified using a numerical value and its unit of measurement The unit of measurement shall be specified in accordance with ISO 11240 and the resulting terminology The symbol and the symbol identifier shall be used
weightQuantity0..1Where applicable, the weight can be specified using a numerical value and its unit of measurement The unit of measurement shall be specified in accordance with ISO 11240 and the resulting terminology The symbol and the symbol identifier shall be used
nominalVolumeQuantity0..1Where applicable, the nominal volume can be specified using a numerical value and its unit of measurement The unit of measurement shall be specified in accordance with ISO 11240 and the resulting terminology The symbol and the symbol identifier shall be used
externalDiameterQuantity0..1Where applicable, the external diameter can be specified using a numerical value and its unit of measurement The unit of measurement shall be specified in accordance with ISO 11240 and the resulting terminology The symbol and the symbol identifier shall be used
shapestring0..1Where applicable, the shape can be specified An appropriate controlled vocabulary shall be used The term and the term identifier shall be used
colorstring0..*Where applicable, the color can be specified An appropriate controlled vocabulary shall be used The term and the term identifier shall be used
imprintstring0..*Where applicable, the imprint can be specified as text
imageAttachment0..*Where applicable, the image can be provided The format of the image attachment shall be specified by regional implementations
scoringCodeableConcept0..1Where applicable, the scoring can be specified An appropriate controlled vocabulary shall be used The term and the term identifier shall be used

Reference​

Official FHIR R4 specification: ProdCharacteristic.