# Get medical notification

Canonical page: https://docs.ovok.com/slim-apis/notifications/get-medical-notification

| Method | Path |
| --- | --- |
| `GET` | `/v1/slim/notifications/medical/:episodeId` |

[Authentication](/authentication) · [Access policies](/access-policies)

Returns one medical notification with its counted readings, addressed by the `episode.id` a feed row carries. Signals decides medical alerts and provides the episode.

**Auth:** Bearer token. The caller must be a practitioner, an admin, a super admin, or hold the "System Owner" access policy. The access policy must grant `Patient:read`, `Device:read` and `Location:read` (admins and super admins skip this check).
**Scope:** The caller's project (from the token), applied on both sides: Signals matches it against the resident's project stamp, and Ovok checks the resolved resident against your project.

## Request [#request]

### Path parameters [#path-parameters]

| Name | Type | Required | Description |
| --- | --- | --- | --- |
| `episodeId` | `string` | Yes | The Signals episode id: the `episode.id` a feed row carries. Not checked for format here; an id that does not exist answers 404. |

## Behaviour [#behaviour]

- Ovok waits up to 5 seconds for Signals. A `503 signals_unavailable` ([`signals_unavailable`](/errors/signals-unavailable)) is not an empty result; retry after `retryAfterSec`.
- `episode` is the Signals episode as Signals returned it: status, open and close times, close reason, aggregates, and `values`. The `values` list contains only readings the episode counted: each firing reading and the reading that recovered it. It omits history rows (`batch-data`, `statistics`, and `presence-batch`), non-readings (including 0, -1, missing values and values at or below 0), and the absent reading that closed an `AWAY` episode. Episodes stored before migration 60 list readings as they did before. Clients should not render a "0 bpm" or "No value" line. Check `episode.truncated`: a long episode returns up to 999 counted readings and sets it to `true`.
- `carehub` adds the resident context: resident, room and bed, device and zone. Its fields are `null` when the resident has no device assigned.
- `acknowledgement` is `null` until someone acknowledges the episode.
- `episode.firedBand` is the band the episode was judged under, as described on `GET /v1/slim/notifications/medical`. It is `null` when it cannot be established.
- `noteCount` is the number of notes on the episode, or `null` when the count could not be established.
- An episode in another project answers 404, the same as one that does not exist. A 404 is never caused by Signals being down.
- A 503 with [`signals_unavailable`](/errors/signals-unavailable) means Signals could not be reached; retry after `retryAfterSec`.

## Example [#example]

```bash
curl -X GET 'https://api.sandbox.ovok.com/v1/slim/notifications/medical/3f1c2b7e-8d4a-4c1e-9b2f-6a7d5e4c3b21' \
  -H "Authorization: Bearer ${OVOK_TOKEN}"
```

## Successful response [#successful-response]

`200` — The episode and its resident context.

```json
{
  "episode": {
    "id": "3f1c2b7e-8d4a-4c1e-9b2f-6a7d5e4c3b21",
    "patientId": "3f1c2b7e-8d4a-4c1e-9b2f-6a7d5e4c3b22",
    "code": "8867-4",
    "system": "http://loinc.org",
    "display": null,
    "status": "OPEN",
    "openedAt": "2026-10-09T07:40:12.000Z",
    "closedAt": null,
    "closeReason": null,
    "lastSampleAt": "2026-10-09T08:05:12.000Z",
    "durationMs": 1500000,
    "observationCount": 6,
    "firingCount": 6,
    "minValue": 118,
    "maxValue": 134,
    "avgValue": 125.5,
    "lastValue": 131,
    "peakValue": 134,
    "peakAt": "2026-10-09T07:55:12.000Z",
    "lastFiringValue": 131,
    "lastFiringAt": "2026-10-09T08:05:12.000Z",
    "lastObservationId": "3f1c2b7e-8d4a-4c1e-9b2f-6a7d5e4c3b41",
    "firedBand": {
      "min": 50,
      "max": 110,
      "triggerVersion": 2
    },
    "values": [
      {
        "observationId": "3f1c2b7e-8d4a-4c1e-9b2f-6a7d5e4c3b42",
        "valueNumber": 118,
        "valueString": null,
        "valueUnit": "beats/min",
        "note": null,
        "observedAt": null,
        "recordedAt": "2026-10-09T07:40:12.000Z"
      },
      {
        "observationId": "3f1c2b7e-8d4a-4c1e-9b2f-6a7d5e4c3b43",
        "valueNumber": 134,
        "valueString": null,
        "valueUnit": "beats/min",
        "note": null,
        "observedAt": "2026-10-09T07:55:12.000Z",
        "recordedAt": "2026-10-09T07:55:13.000Z"
      },
      {
        "observationId": "3f1c2b7e-8d4a-4c1e-9b2f-6a7d5e4c3b41",
        "valueNumber": 131,
        "valueString": null,
        "valueUnit": "beats/min",
        "note": null,
        "observedAt": "2026-10-09T08:05:12.000Z",
        "recordedAt": "2026-10-09T08:05:13.000Z"
      }
    ],
    "truncated": false
  },
  "carehub": {
    "patientId": "3f1c2b7e-8d4a-4c1e-9b2f-6a7d5e4c3b22",
    "patientName": "demo-resident",
    "locationId": "3f1c2b7e-8d4a-4c1e-9b2f-6a7d5e4c3b23",
    "locationName": "Room 101",
    "room": "101",
    "bed": "A",
    "floor": "1",
    "deviceId": "DEMO-0001",
    "deviceMedplumId": "3f1c2b7e-8d4a-4c1e-9b2f-6a7d5e4c3b24",
    "deviceName": "Demo Bed Sensor",
    "organizationId": "3f1c2b7e-8d4a-4c1e-9b2f-6a7d5e4c3b25",
    "organizationName": "Demo Care Home"
  },
  "acknowledgement": null,
  "noteCount": 0
}
```

The detail has the same blocks as a feed row, and `episode` also carries the readings.

The response has three blocks (`episode`, `carehub`, `acknowledgement`) and a `noteCount`. A nullable field is always present, as `null` when it has no value.

| Field | Type | Description |
| --- | --- | --- |
| `episode` | `object` | The Signals episode with its aggregates, passed through as Signals reported it. One episode is a run of readings outside the band. |
| `episode.id` | `string` | The episode id. Use it with `GET /v1/slim/notifications/medical/{episodeId}` and `POST /v1/slim/notifications/medical/{episodeId}/ack`. |
| `episode.patientId` | `string` | The resident's id at Signals. It equals `carehub.patientId` for residents created recently; use `carehub.patientId` with other Ovok routes. |
| `episode.code` | `string` | The vital the episode is about: a LOINC code such as `8867-4` (heart rate) or `9279-1` (respiratory rate), or `PI` for perfusion index. |
| `episode.system` | `string \| null` | The code system of `code`, for example `http://loinc.org`. |
| `episode.display` | `string \| null` | Display text for `code`, when Signals has one. |
| `episode.status` | `"OPEN"` \| `"CLOSED"` | Whether the episode is still running. |
| `episode.openedAt` | `string (ISO 8601 date-time)` | When the episode opened. |
| `episode.closedAt` | `string (ISO 8601 date-time) \| null` | When it closed. `null` while it is open. |
| `episode.closeReason` | `"RECOVERED"` \| `"TIMEOUT"` \| `"ACKNOWLEDGED"` \| `"CROSSED"` \| `"THRESHOLD_CHANGED"` \| `"AWAY"` \| `"STALE"` \| `"MANUAL"` \| `null` | Why it closed; `null` while open. See [How an episode behaves](/signals/connected-ovok#how-an-episode-behaves) for each meaning. |
| `episode.lastSampleAt` | `string (ISO 8601 date-time) \| null` | When the newest reading was folded in. On an open episode it shows how fresh the data is. |
| `episode.durationMs` | `number \| null` | The episode length in milliseconds, as Signals reports it. |
| `episode.observationCount` | `number \| null` | How many readings were folded into the episode. |
| `episode.firingCount` | `number \| null` | How many of those readings were outside the band. |
| `episode.minValue` | `number \| null` | The lowest reading in the episode. |
| `episode.maxValue` | `number \| null` | The highest reading in the episode. |
| `episode.avgValue` | `number \| null` | The average reading in the episode. |
| `episode.lastValue` | `number \| null` | The newest reading folded in. On a recovered episode this is the recovery reading. |
| `episode.peakValue` | `number \| null` | The peak reading of the episode. |
| `episode.peakAt` | `string (ISO 8601 date-time) \| null` | When the peak reading was recorded. |
| `episode.lastFiringValue` | `number \| null` | The last reading outside the band. This is the value a closed episode should headline. `null` for episodes stored before Signals tracked it; use `peakValue` then. |
| `episode.lastFiringAt` | `string (ISO 8601 date-time) \| null` | When the last reading outside the band was recorded. |
| `episode.lastObservationId` | `string \| null` | The id of the last evaluated reading folded in. On a recovered episode, the reading that closed it. Match it against `values[].observationId` on the detail route. |
| `episode.firedBand` | `object \| null` | The band the episode was judged under: the band Signals recorded when it fired, or else the band rebuilt from its configuration history. It is not the resident's current band, so editing a threshold does not change past episodes. `null` when the band cannot be established; that never fails the read. |
| `episode.firedBand.min` | `number \| null` | The lower limit, or `null` when the band has no lower limit. |
| `episode.firedBand.max` | `number \| null` | The upper limit, or `null` when the band has no upper limit. |
| `episode.firedBand.triggerVersion` | `number \| null` | The version of the resident's threshold rule the band belongs to. |
| `episode.values` | `object[]` | Only readings the episode counted: each firing reading and the reading that recovered it. Excludes `batch-data`, `statistics`, and `presence-batch` history rows, non-readings, and the absent reading that closed an `AWAY` episode. Older episodes stored before migration 60 list readings as before. |
| `episode.values[].observationId` | `string` | The reading's id. |
| `episode.values[].valueNumber` | `number \| null` | The numeric value. |
| `episode.values[].valueString` | `string \| null` | The value as text, when it is not numeric. |
| `episode.values[].valueUnit` | `string \| null` | The unit, for example `beats/min`. |
| `episode.values[].note` | `string \| null` | A note recorded with the reading. |
| `episode.values[].observedAt` | `string (ISO 8601 date-time) \| null` | The device's event time. `null` when the reading carries none. |
| `episode.values[].recordedAt` | `string (ISO 8601 date-time)` | When Signals stored the reading. It is the clock the episode window uses, so a chart plotted on it stays inside the episode's bounds. |
| `episode.truncated` | `boolean` | `true` when more than 999 counted readings exist and the returned `values` list is capped. |
| `carehub` | `object` | The resident context Signals does not hold. Every field except `carehub.patientId` is `null` when the resident has no device assigned or the context could not be read. |
| `carehub.patientId` | `string (uuid)` | The resident's Ovok `Patient.id`. Use it for the `patient` filter and for other Slim routes. |
| `carehub.patientName` | `string \| null` | The resident's label (their Resident ID): the Patient's nickname, otherwise its official given name, otherwise the first name on file. |
| `carehub.locationId` | `string (uuid) \| null` | The room's Location id. |
| `carehub.locationName` | `string \| null` | The room's name. |
| `carehub.room` | `string \| null` | The room label, from the Location's type codings. |
| `carehub.bed` | `string \| null` | The bed label, from the Location's type codings. |
| `carehub.floor` | `string \| null` | The floor label, from the Location's type codings. |
| `carehub.deviceId` | `string \| null` | The device serial that the Slim device routes use. |
| `carehub.deviceMedplumId` | `string (uuid) \| null` | The device's FHIR `Device.id`. |
| `carehub.deviceName` | `string \| null` | The device's display name. |
| `carehub.organizationId` | `string (uuid) \| null` | The zone's id. A zone is the device's managing Organization. |
| `carehub.organizationName` | `string \| null` | The zone's name. |
| `acknowledgement` | `object \| null` | `null` until someone acknowledges the episode. |
| `acknowledgement.acknowledgedAt` | `string (ISO 8601 date-time)` | When the episode was acknowledged. |
| `acknowledgement.acknowledgedBy` | `string \| null` | Ovok's client id at Signals. It is the same value for every acknowledgement made through Ovok. It is not a person: do not show it as a name. |
| `acknowledgement.acknowledgedActor` | `object \| null` | Who acknowledged. `null` for acknowledgements made before Ovok sent an actor, and when the session had no profile. |
| `acknowledgement.acknowledgedActor.reference` | `string` | The caller's profile reference, normally `Practitioner/{id}`. Admin and service sessions can carry another profile type. |
| `acknowledgement.acknowledgedActor.display` | `string \| null` | The caller's display name, captured when the episode was acknowledged. |
| `noteCount` | `integer \| null` | The number of notes on this episode. `null` when the count could not be established. |

## Errors [#errors]

| Status | Meaning |
| --- | --- |
| [`401`](/errors/unauthenticated) | Bearer token is missing, invalid or expired. |
| [`403`](/errors/forbidden) | You are not a practitioner, admin or System Owner, you lack `Patient:read`, `Device:read` or `Location:read`, your session has no project, or you cannot access the project. |
| [`404`](/errors/not-found) | No episode with this id exists in your project, or its resident cannot be resolved into your project. |
| [`503`](/errors/service-unavailable) | Signals could not be reached, or answered with an error other than "not found" (`error` is [`signals_unavailable`](/errors/signals-unavailable)). The body carries `error` and `retryAfterSec`, and the `Retry-After` header carries the same delay in seconds. This is not an empty result: retry after the delay. |