Saves the home's threshold configuration in the v2 shape. mode is required on every settings field; patient is not a valid mode here.
Auth: Bearer token. The caller must be a practitioner, an admin, a super admin, or hold the "System Owner" access policy. The access policy must grant PlanDefinition:update (an admin or super admin who holds no access policy skips this check).
Scope: The caller's project (from the token).
Behaviour
settings.heartRateandsettings.respiratoryRate:mode: 'organization'withenabled,minandmax. The home's band is absolute;mode: 'baseline'answers 422, because a resident without a baseline of their own would get no alarm from it. Set baseline limits per resident withPUT /v2/slim/threshold/patient/{patientId}.settings.outOfBed:mode: 'organization'withenabledandmaxDurationSeconds(a multiple of 60, from 0 to 86400), plus an optionaldeviationPercent(an integer from 5 to 300, ornullto switch it off). With it, every resident on the home's out-of-bed setting alerts once an exit runs that far past their own usual exit, if that is sooner thanmaxDurationSeconds. Omit it to keep the stored value.settings.bedTimePeriod:mode: 'organization'withstartandend(HH:MM:SS).endequal tostartmeans 24 hours;endbeforestartcrosses midnight.settings.oxygenSaturation,pulseRate,perfusionIndex,bodyTemperature(each optional):{ mode: 'organization', enabled, min, max }, the home's default for every resident. Either bound may benullfor a one-sided limit. An enabled vital needs at least one bound, andminmust be belowmax. Omitting one, or sendingnull, keeps what is stored. Disabling one removes its rules in Signals.ranges(optional): the range each vital's limits may take, for the home and every resident. Per vital,{ min, max }withmin < max, inside heart rate 20–300, respiratory rate 4–150, SpO₂ 50–100, pulse 20–300, perfusion index 0–20 and body temperature 30–45. A vital left out keeps its stored range, or the default: heart rate 40–120, respiratory rate 4–60, SpO₂ 70–100, pulse 40–120, perfusion index 0–20, body temperature 34–42. A range for SpO₂, pulse, perfusion index or temperature is kept with that vital's setting, so the home must have set the vital (it may be disabled); otherwise the PUT answers 422 onranges.<vital>.- Every enabled limit must sit inside its range, counting
rangesin the same request. One outside answers 422 naming the field (for examplesettings.heartRate.max) and nothing is saved. A disabled band is not checked. - Narrowing a range does not rewrite residents whose limits fall outside it. A resident's next change to such a limit must fit; their other edits still save.
- Medical limits (heart rate, respiratory rate, the optional vitals, the out-of-bed limit and the bed-time window) are evaluated by Signals. Every save is all or nothing, one that changes nothing included: it writes the home's settings to Signals and answers only once Signals holds them, and nothing writes them later. Residents following the home follow it at once, the out-of-bed band included (Signals applies it to each resident's usual exit); a resident with limits of their own keeps them.
- Homes with many residents take longer: the save gives up after about 25 seconds and puts back what it wrote. Putting back can take longer than the gateway allows, so the caller may get a 504 while it finishes. Read the limits (
GET /v2/slim/threshold) before sending the save again: until the undo is done, another save answers 409. - If any of that fails, everything the save changed is put back and it answers an error with
saved: false. Nothing is stored; send the save again:- 409: another save of this home's limits is running, the home is moving to another Signals tenant, or the home's limits were saved while this one ran.
- 502: the save ran out of time, or Signals did not take the limits.
- 500: putting the previous limits back failed too. The message says which side kept the new limits; save the home's limits again.
- If the stored thresholds cannot be read, the PUT answers 502 and nothing is saved.
- Unknown keys are stripped, so a GET response can be sent back as a PUT body, with two exceptions: a heart-rate or respiratory-rate field still stored on baseline (see above), and a range the GET reports for an optional vital the home has never set.
- A change-history entry is written for a save that stands. The response is the saved configuration, with
signalsSync: { status: 'ok' }. - The v1 route
PUT /v1/slim/thresholdis deprecated in favour of this one.
Example
curl -X PUT 'https://api.sandbox.ovok.com/v2/slim/threshold' \ -H 'Authorization: Bearer eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJpYXQiOjE3NjcyNjg4MDAsImV4cCI6MTc2NzI3MjQwMH0.Ql3B_ztDvctlyZ2z0vp4sl3ExXRQGkzmxdmTAqxNzZk' \ -H 'Content-Type: application/json' \ -d '{ "settings": { "heartRate": { "mode": "organization", "enabled": true, "min": 40, "max": 120 }, "respiratoryRate": { "mode": "organization", "enabled": true, "min": 8, "max": 25 }, "outOfBed": { "mode": "organization", "enabled": true, "maxDurationSeconds": 900 }, "bedTimePeriod": { "mode": "organization", "start": "19:00:00", "end": "09:00:00" } } }'bearerheader
AuthorizationBearer <JWT>application/json- body
settings*ranges?v2 threshold updated successfully.
application/json- response
id*stringprojectId*stringupdatedAt*stringsettings*ranges*signalsSync*|curl -X PUT 'https://api.sandbox.ovok.com/v2/slim/threshold' \ -H 'Content-Type: application/json' \ -d '{ "settings": { "heartRate": { "mode": "organization", "enabled": true, "min": 20, "max": 20 }, "respiratoryRate": { "mode": "organization", "enabled": true, "min": 4, "max": 4 }, "outOfBed": { "mode": "organization", "enabled": true, "maxDurationSeconds": 0 }, "bedTimePeriod": { "mode": "organization", "start": "string", "end": "string" } }}'Example Response
{ "id": "string", "projectId": "string", "updatedAt": "string", "settings": { "heartRate": { "mode": "organization", "enabled": true, "min": 0, "max": 0 }, "respiratoryRate": { "mode": "organization", "enabled": true, "min": 0, "max": 0 }, "outOfBed": { "mode": "organization", "enabled": true, "maxDurationSeconds": 0, "deviationPercent": 0, "baselineAverage": 0, "effectiveMaxDurationSeconds": 0 }, "bedTimePeriod": { "mode": "organization", "start": "string", "end": "string", "timezone": "string" }, "oxygenSaturation": { "mode": "organization", "enabled": true, "min": 0, "max": 0 }, "pulseRate": { "mode": "organization", "enabled": true, "min": 0, "max": 0 }, "perfusionIndex": { "mode": "organization", "enabled": true, "min": 0, "max": 0 }, "bodyTemperature": { "mode": "organization", "enabled": true, "min": 0, "max": 0 } }, "ranges": { "heartRate": { "min": 0, "max": 0 }, "respiratoryRate": { "min": 0, "max": 0 }, "oxygenSaturation": { "min": 0, "max": 0 }, "pulseRate": { "min": 0, "max": 0 }, "perfusionIndex": { "min": 0, "max": 0 }, "bodyTemperature": { "min": 0, "max": 0 } }, "signalsSync": { "status": "ok" }}